• Offer Profile
  • We have four decades of internationally recognized experience in the research and development of thick-film hybrid circuits, pressure sensors and electronics for various applications in medicine, industrial equipment and vehicles.

    We provide a full range of services covering the entire process from development to batch production in order to create custom-made products based on anticipating the needs of our customers, our experience in selling our own products and development and manufacturing for known customers.

Product Portfolio
  • Industrial Sensors

  • CUSTOMISED PRODUCTS

    The hybrid technology, used in the HYB production process, merges various technologies with the purpose to produce high-quality and powerful pressure sensors.

    With an extremely short development cycle HYB offers customised solutions from minor changes of the standard hybysens® product to the development of a completely new pressure sensor based on the purchaser’s requirements.

      • HYBYSENS® PRODUCTS

      • PRESSURE SENSORS AND SWITCHES

        The hybysens® product group comprises pressure, temperature, and force sensors, which get built into various appliances, from medical devices (dialysis machines, respirators) to automated lines, from household appliances to cars.

          • SERIES 1000

            • Easy to use package - SMD
            • Gage and absolute configuration
            • Digital and analog version
            • For air and non-corrosive gases
            • 50 mBar - 7 Bar
          • SERIES 2000

            • Standard metal 19 mm housing
            • Digital and analog version
            • Gage configuration
            • Temperature compensated
            • 20 mBar – 7 Bar
          • SERIES 3000

            • Gage, differential and absolute configuration
            • Digital and analog version
            • Temperature compensated
            • 10 mBar – 7 Bar
          • SERIES 4000

            • Gage, differential and absolute configuration
            • Digital and analog version
            • Temperature compensated
            • 10 mBar – 7 Bar
          • SERIES 5000

            • Pressure switch or/and pressure sensor
            • Absolute and gage configuration
            • Digital version
            • Standard M8 output connector
            • Over-voltage and over-current protection
            • 20 mBar – 7 Bar
          • SERIES 6000

            • Barometric pressure sensor
            • 1 Bar absolute configuration
            • MAP application
          • SERIES 7000

            • Low-temperature co-fired ceramic (LTCC) sensor technology
            • Compatible with many types of aggressive media
            • Wet-wet applications
            • Differential configuration
            • A patented design of sensor
            • 100 mbar to 10 bar
        • Medical Devices

        • The medical programme is the result of proper development and stems from many years of experience in pressure sensor production. The most extensive is the invasive blood pressure measurement programme, trademarked hybymed® and standalone components which are also available for further installation.

          An ISO 13485 certified and maintained quality management system and proper production in clean room (Class 8 by ISO 14644-1)  guarantee the high and consistent quality of our products.

          A detailed assortment of hybymed® products is available in the  catalogue, or you may contact our Customer Support Service.

          All hybymed® products are CE certified.

            • IBPM SYSTEM

            • Hybymed® IBPM system offers complete, precise, and reliable information on invasive blood pressure via one to four canals. There is also a special, neonatal configuration.

              ADVANTAGES

              • Wireless Disposable sensor creates minimal waste
              • Simple “click-on” attachment of the sensor to the contact plate
              • Single cable from contact plate to monitor
              • Compatible with most monitors

               

              TECHNICAL SPECIFICATIONS

              • Standard configuration with single, double, triple, or quadruple sensor sites.
              • Calibrated and stabilised sensor, compatible with the ANSI/AAMI BP22 and IEC 60601-2-34 standards.
              • Standard tube length of 170 cm.

               

            • IBPM PLUS SYSTEM

            • Hybymed® IBPM plus system is an upgrade to the hybymed®  IBPM system because it additionally enables closed blood sampling system. Waste of all types and the possibility of IV line and subsequently patient infection are reduced, and medical personnel are protected from direct blood contact.

              ADVANTAGES

              • Closed, needleless, “in line” clean arterial blood sampling system.
              • Part of the invasive arterial blood pressure measurement line.
              • Standardises the blood sampling procedure from the aspects of repeatability, accuracy, and safety.
              • Prevents bubble formation during the taking of samples.
              • Simple wash-out of blood residuum.

              TECHNICAL SPECIFICATIONS

              • 2 ml reservoir.
              • Closed three-pole valve with automatic rinsing and standard Luer sampling gates.
              • 30 cm distance of the sampling gates from the patient’s Luer connector.

               

               

            • COMPONENTS AND ACCESSORIES

            • Components and accessories simplify the everyday use of hybymed® products. Most of them are permanent. The most popular are presented below, whereas a full list is available in the catalogue. You may also contact our Customer Support Service

              • Contact boards
              • Holders
              • CBSS Holder
              • Monitor cables
          • STANDALONE COMPONENTS

          • The standalone components are intended for further installation in various systems and are not available for direct use in hospitals. The most demanded are the pressure sensor and the reservoir for closed blood sampling system.
              • BLOOD PRESSURE SENSOR

              • The sensor is a key component in invasive blood pressure measurement.

                TECHNICAL SPECIFICATIONS

                • Compatible with the ANSI/AAMI BP22 and IEC 60601-2-34 standards.SI/AAMI BP22 in IEC 60601-2-34
                • Calibrated and stabilised regarding sensitivity, linearity, and the zero point.
                • Sensitivity: 5 μV/V/mmHg ± 2%
                • Zero drift: less than ±1.0 mmHg/8 h
                • “Click-on” or sliding housing design
                • Sensor with direct contacts, wireless
                • Wide array of accessories for easier use
                • Colour-coded to minimise incorrect connections
                • In combination with valves and/or rinsing system
                • Configured according to specifications of the final user
              • CLOSED BLOOD SAMPLING RESERVOIR

              • The reservoir enables pure arterial blood sampling.

                TECHNICAL SPECIFICATIONS

                • 2 ml reservoir
                • Closed, needleless, “in-line” system
                • Standardises the blood sampling procedure from the aspects of repeatability, accuracy, and safety.
                • Part of the invasive arterial blood pressure measurement line.
                • Prevents bubble formation.
                • Enables single-hand manipulation.
                • Reduces blood loss from sampling.
                • Minimises the IV line infection risk.
                • Compatible with the CBSS holder.
                • Customisation for the final user comprises typical volume, connection tube diameter, and interface to the holder